Line 10: | Line 10: | ||
the readout time in seconds for the parameter file will be: | the readout time in seconds for the parameter file will be: | ||
- | < | + | < |
+ | **For singleband images :** | ||
+ | readout = (echospacing * (acquisitionmatrix[0] * (percentsampling/ | ||
echospacing in the BXH header is in microseconds | echospacing in the BXH header is in microseconds | ||
+ | |||
+ | |||
+ | **For mutli-band images the readout calculation is more complex: | ||
+ | readout = ( ( ceil ((1/ | ||
+ | |||
+ | EffectiveEchoSpacing = TotalReadoutTime/ | ||
+ | |||
+ | AcquisitionMatrixPE = the acquisition size of the data ( acquisitionmatrix[0] ) | ||
+ | reconMatrixPE = the size of the reconstructed data ( may be different from acquisition because of FFT rules ) | ||
+ | Round_factor = 4 if partial fourier ( PFF is in scanoptions ), 2 if full fourier. | ||
+ | Asset_R_factor = the reciprocal of the first value of dcm tag (0043,1083) | ||
+ | |||
</ | </ | ||
Line 297: | Line 311: | ||
dwipreproc dwi.mif dwi_corr.mif -rpe_all -pe_dir AP -readout_time 0.10656 -debug | dwipreproc dwi.mif dwi_corr.mif -rpe_all -pe_dir AP -readout_time 0.10656 -debug | ||
- | -rpe_all signals that you've replicated | + | - rpe_all signals that you've replicated |
- | A | + | - pe_dir is the phase encode direction of your regular acquisition |
- | LL the directions with a rpe acquisition | + | - readout_time from above |
- | -pe_dir is the phase encode direction of your regular acquisition | + | |
- | -readout_time from above | + | |
</ | </ | ||