This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
biac:experimentalcontrol:biac5hardware [2020/08/25 19:29] cmp12 |
biac:experimentalcontrol:biac5hardware [2021/08/05 14:32] cmp12 |
||
---|---|---|---|
Line 6: | Line 6: | ||
* Second monitor video output connected to KVM switch (CPU 2) | * Second monitor video output connected to KVM switch (CPU 2) | ||
* Stereo sound output to audio switch boxes (CPU1 - switch 1) | * Stereo sound output to audio switch boxes (CPU1 - switch 1) | ||
- | * NeuroScan 4-button response box via E-Prime SRbox (COM1: 19200 baud, 8 bits, no parity) | + | * E-Prime SRbox (COM1: 19200 baud, 8 bits, no parity) |
* GE scanner cardiac/ | * GE scanner cardiac/ | ||
* Serial cable to Kulpe computer (COM3: 56K baud, 8 bits) | * Serial cable to Kulpe computer (COM3: 56K baud, 8 bits) | ||
Line 15: | Line 15: | ||
* must check this mode if power is cycled to the interface | * must check this mode if power is cycled to the interface | ||
- | * MagConcepts | + | * Current Design 2 axis, 2 button joystick |
+ | * autoconfigure | ||
+ | * HID Joystick | ||
+ | * USB - Tethyx | ||
+ | * after use switch back to button box with above settings | ||
* Measurement Computing Analog/ | * Measurement Computing Analog/ | ||
* to reset AD device disconnect USB cable. | * to reset AD device disconnect USB cable. | ||
Line 64: | Line 69: | ||
==== MCC digital channel to BIOPAC digital channel mapping ==== | ==== MCC digital channel to BIOPAC digital channel mapping ==== | ||
^MCC ^BIOPAC^ | ^MCC ^BIOPAC^ | ||
- | | | + | | |
- | A0 | “Trig” | | + | |
| DA1 | D9 | | | DA1 | D9 | | ||
| DA2 | D10| | | DA2 | D10| | ||
Line 73: | Line 77: | ||
| DA6 | D14| | | DA6 | D14| | ||
| DA7 | D15| | | DA7 | D15| | ||
+ | |||
+ | |||
==== See also ==== | ==== See also ==== | ||
* [[http:// | * [[http:// |