biac:experimentalcontrol:biac5hardware [2021/08/05 14:34]
cmp12
biac:experimentalcontrol:biac5hardware [2022/04/20 17:52]
tbh6
Line 1: Line 1:
 =====Hardware device connections at BIAC-5 3T (MR750) scanner===== =====Hardware device connections at BIAC-5 3T (MR750) scanner=====
-==== BIAC5 3T -- Darwin computer====+==== Darwin computer ====
 Darwin is our primary stimulus presentation computer.  It is usually connected to the monitor on the left.\\ Darwin is our primary stimulus presentation computer.  It is usually connected to the monitor on the left.\\
 Darwin has the following peripheral hardware connected: Darwin has the following peripheral hardware connected:
Line 23: Line 23:
      * to reset AD device disconnect USB cable.      * to reset AD device disconnect USB cable.
   * E-Prime dongle connected to USB port   * E-Prime dongle connected to USB port
-  * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0)+  * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0), biopac analog CH 9
   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse
   * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4   * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4
   * Biopac cardiac signal connected as MeasComp analog input (pulse ch3, OxSat ch4), biopac analog ( o2 ch3, pulse wave ch7, pulse rate ch11)   * Biopac cardiac signal connected as MeasComp analog input (pulse ch3, OxSat ch4), biopac analog ( o2 ch3, pulse wave ch7, pulse rate ch11)
   * BioPac GSR signal connected as MeasComp analog input (ch 1)   * BioPac GSR signal connected as MeasComp analog input (ch 1)
-  * BioPac EGG signal connected as MeasComp analog input (ch 2) +  * <del>BioPac EGG signal connected as MeasComp analog input (ch 2)</del> 
-  * Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input+  * <del>Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input</del>
   * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In   * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In
  
 ==== BIAC5 3T -- Kulpe computer==== ==== BIAC5 3T -- Kulpe computer====
-Kulpe is our accessory computer. It is usually connected to the monitor on the right.\\+Kulpe is  
 +our accessory computer. It is usually connected to the monitor on the right.\\
 Kulpe has the following peripheral hardware connected: Kulpe has the following peripheral hardware connected:
   * Keyboard, video, and mouse connected to KVM video switch (CPU 3)   * Keyboard, video, and mouse connected to KVM video switch (CPU 3)