This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Next revision Both sides next revision | ||
biac:experimentalcontrol:biac5hardware [2022/02/23 13:42] cmp12 |
biac:experimentalcontrol:biac5hardware [2022/04/20 17:52] tbh6 |
||
---|---|---|---|
Line 23: | Line 23: | ||
* to reset AD device disconnect USB cable. | * to reset AD device disconnect USB cable. | ||
* E-Prime dongle connected to USB port | * E-Prime dongle connected to USB port | ||
- | * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0) | + | * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0), biopac analog CH 9 |
* Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse | * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse | ||
* Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4 | * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4 | ||
Line 29: | Line 29: | ||
* BioPac GSR signal connected as MeasComp analog input (ch 1) | * BioPac GSR signal connected as MeasComp analog input (ch 1) | ||
* < | * < | ||
- | * Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input | + | * <del>Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input</ |
* Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In | * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In | ||