Line 9: | Line 9: | ||
* GE scanner cardiac/ | * GE scanner cardiac/ | ||
* Serial cable to Kulpe computer (COM3: 56K baud, 8 bits) | * Serial cable to Kulpe computer (COM3: 56K baud, 8 bits) | ||
+ | |||
* Current Design 8-button serial response device (USB keyboard device, default mode) | * Current Design 8-button serial response device (USB keyboard device, default mode) | ||
* button box mode: " | * button box mode: " | ||
Line 19: | Line 20: | ||
* USB - Tethyx | * USB - Tethyx | ||
* after use switch back to button box with above settings | * after use switch back to button box with above settings | ||
+ | |||
+ | * Current Design Trackball 2 ( shared between 2 scanners ) | ||
+ | * autoconfigure | ||
+ | * HID HHSC-TRK-2 ( track 2 and comp seem to do the exact same thing ) | ||
+ | * roll ball around to calibrate | ||
+ | * after use switch back to button box with above settings | ||
+ | |||
* Measurement Computing Analog/ | * Measurement Computing Analog/ | ||
* to reset AD device disconnect USB cable. | * to reset AD device disconnect USB cable. | ||
* E-Prime dongle connected to USB port | * E-Prime dongle connected to USB port | ||
- | * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0) | + | * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0), biopac analog CH 9 |
* Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse | * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse | ||
* Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4 | * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4 | ||
Line 29: | Line 37: | ||
* BioPac GSR signal connected as MeasComp analog input (ch 1) | * BioPac GSR signal connected as MeasComp analog input (ch 1) | ||
* < | * < | ||
- | * Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input | + | * <del>Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input</ |
* Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In | * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In | ||