biac:experimentalcontrol:biac5hardware [2022/02/23 13:42]
cmp12
biac:experimentalcontrol:biac5hardware [2023/03/24 18:40] (current)
cmp12
Line 9: Line 9:
   * GE scanner cardiac/respiratory cable (COM4)   * GE scanner cardiac/respiratory cable (COM4)
   * Serial cable to Kulpe computer (COM3: 56K baud, 8 bits)   * Serial cable to Kulpe computer (COM3: 56K baud, 8 bits)
 +
   * Current Design 8-button serial response device (USB keyboard device, default mode)   * Current Design 8-button serial response device (USB keyboard device, default mode)
     * button box mode: "HHSC-2x4-C" response box     * button box mode: "HHSC-2x4-C" response box
Line 19: Line 20:
     * USB - Tethyx     * USB - Tethyx
     * after use switch back to button box with above settings     * after use switch back to button box with above settings
 +
 +  * Current Design Trackball 2 ( shared between 2 scanners )
 +    * autoconfigure
 +    * HID HHSC-TRK-2 ( track 2 and comp seem to do the exact same thing )
 +    * roll ball around to calibrate
 +    * after use switch back to button box with above settings
 +
  
   * Measurement Computing Analog/Digital data acquisition device (USB-1208FS, dev=0, 8 a/d chans)   * Measurement Computing Analog/Digital data acquisition device (USB-1208FS, dev=0, 8 a/d chans)
      * to reset AD device disconnect USB cable.      * to reset AD device disconnect USB cable.
   * E-Prime dongle connected to USB port   * E-Prime dongle connected to USB port
-  * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0)+  * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0), biopac analog CH 9
   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse
   * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4   * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4
Line 29: Line 37:
   * BioPac GSR signal connected as MeasComp analog input (ch 1)   * BioPac GSR signal connected as MeasComp analog input (ch 1)
   * <del>BioPac EGG signal connected as MeasComp analog input (ch 2)</del>   * <del>BioPac EGG signal connected as MeasComp analog input (ch 2)</del>
-  * Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input+  * <del>Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input</del>
   * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In   * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In
  