biac:experimentalcontrol:biac6hardware [2014/12/15 16:53]
cmp12
biac:experimentalcontrol:biac6hardware [2014/12/15 19:48]
cmp12 [BIAC6 3T -- Mach computer]
Line 18: Line 18:
   * E-Prime dongle (USB)   * E-Prime dongle (USB)
   * Scanner trigger cable connected as input to E-Prime SR box (code=16), and MeasComp analog (ADC3)   * Scanner trigger cable connected as input to E-Prime SR box (code=16), and MeasComp analog (ADC3)
-  * BioPac Respiratory belt signal connected as MeasComp analog input 0 (ADC0)+  * BioPac Respiratory belt signal connected as MeasComp analog input 0 (ADC0), biopac analog ch4
   * BioPac Cardiac signal connected as MeasComp analog input 1 (ADC1), biopac analog ( o2 ch2, pulse wave ch6, pulse rate ch10 )   * BioPac Cardiac signal connected as MeasComp analog input 1 (ADC1), biopac analog ( o2 ch2, pulse wave ch6, pulse rate ch10 )
   * BioPac GSR signal connected as MeasComp analog input 2 (ADC2), biopack analog ch1   * BioPac GSR signal connected as MeasComp analog input 2 (ADC2), biopack analog ch1