User Tools

Site Tools


biac:experimentalcontrol:biac6hardware

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
biac:experimentalcontrol:biac6hardware [2016/09/07 13:23]
cmp12
biac:experimentalcontrol:biac6hardware [2022/02/23 18:44]
cmp12
Line 7: Line 7:
   * Second monitor video output connected to video switch (CPU 2)   * Second monitor video output connected to video switch (CPU 2)
   * Stereo sound output to audio switch boxes   * Stereo sound output to audio switch boxes
 + 
   * Current Design 8-button serial response device (USB)   * Current Design 8-button serial response device (USB)
     * button box mode: "HHSC-2x4-C" response box     * button box mode: "HHSC-2x4-C" response box
     * button mode : "HID NAR 12345" (**003**)      * button mode : "HID NAR 12345" (**003**) 
       * must check this mode if power is cycled to the interface       * must check this mode if power is cycled to the interface
-  * MagConcepts Joystick (USB Gaming device)+  * Current Design 2 axis, 2 button joystick shared between 2 scanners ) 
 +    * autoconfigure 
 +    * HID Joystick 
 +    * USB - Tethyx 
 +    * after use switch back to button box with above settings 
   * E-Prime SR box (no button box, just scanner trigger) (COM1: 19200 baud, 8 bits, no parity)   * E-Prime SR box (no button box, just scanner trigger) (COM1: 19200 baud, 8 bits, no parity)
   * Video switch serial cable on **COM2**   * Video switch serial cable on **COM2**
Line 20: Line 26:
   * BioPac Respiratory belt signal connected as MeasComp analog input 0 (ADC0), biopac analog ch4   * BioPac Respiratory belt signal connected as MeasComp analog input 0 (ADC0), biopac analog ch4
   * BioPac Cardiac signal connected as MeasComp analog input 1 (ADC1), biopac analog ( pulse wave ch6 )   * BioPac Cardiac signal connected as MeasComp analog input 1 (ADC1), biopac analog ( pulse wave ch6 )
-  * BioPac GSR signal connected as MeasComp analog input 2 (ADC2), biopack analog ch1 +  * BioPac GSR signal connected as MeasComp analog input 2 (ADC2), biopac analog ch1 
-  * Scanner trigger signal connected as MeasComp analog input 3 (ADC3)+  * Scanner trigger signal connected as MeasComp analog input 3 (ADC3), biopac analog ch9
   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse
    
biac/experimentalcontrol/biac6hardware.txt · Last modified: 2024/04/16 14:21 by cmp12