biac:experimentalcontrol:biac5hardware
This is an old revision of the document!
Hardware device connections at BIAC-5 3T (750) scanner
BIAC5 3T -- Darwin computer
Darwin is our primary stimulus presentation computer. It is usually connected to the monitor on the left.
Darwin has the following peripheral hardware connected:
- Keyboard, video, and mouse connected to KVM video switch (CPU 1)
- Second monitor video output connected to KVM switch (CPU 2)
- Stereo sound output to audio switch boxes (CPU1 - switch 1)
- NeuroScan 4-button response box via E-Prime SRbox (COM1: 19200 baud, 8 bits, no parity)
- GE scanner cardiac/respiratory cable (COM4)
- Serial cable to Kulpe computer (COM3: 56K baud, 8 bits)
- Serial cable to KVM video switch (COM2)
- Current Design 8-button serial response device (USB keyboard device, default mode)
- button box mode: “HHSC-2×4-C” response box
- button mode : “HID NAR 12345” (003)
- must check this mode if power is cycled to the interface
- MagConcepts Joystick (USB Gaming device)
- Measurement Computing Analog/Digital data acquisition device (USB-1208FS, dev=0, 8 a/d chans)
- to reset AD device disconnect USB cable.
- E-Prime dongle connected to USB port
- Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0)
- Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse
- Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor)
- Biopac cardiac signal connected as MeasComp analog input (pulse ch3, OxSat ch4), biopac analog ( o2 ch3, pulse wave ch7, pulse rate ch11)
- BioPac GSR signal connected as MeasComp analog input (ch 1)
- BioPac EGG signal connected as MeasComp analog input (ch 2)
- Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input
- Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In
BIAC5 3T -- Kulpe computer
Kulpe is our accesory computer. It is usually connected to the monitor on the right.
Kulpe has the following peripheral hardware connected:
- Keyboard, video, and mouse connected to KVM video switch (CPU 3)
- BioPac communication (RJ45) cable
- Serial cable to Darwin computer (COM1)
BIAC5 3T -- Other devices
- DVD player, video output connected to KVM switch (CPU 5)
- DVD player, sound connected to Audio switch (DVD - switch 3)
- Stereo sound jack for I-pod, MP3, etc connected to Audio switch (Aux - switch 4)
See also:
USB-1208FS,Measurement Computing Inc.,Universal Library User Guide
biopac manual
biac/experimentalcontrol/biac5hardware.1407530694.txt.gz · Last modified: 2024/06/21 15:41 (external edit)