User Tools

Site Tools


biac:experimentalcontrol:biac5hardware

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
biac:experimentalcontrol:biac5hardware [2014/08/09 02:01]
favorini
biac:experimentalcontrol:biac5hardware [2021/10/21 19:02]
cmp12 [BIAC5 3T -- Darwin computer]
Line 1: Line 1:
-====Hardware device connections at BIAC-5 3T (750) scanner==== +=====Hardware device connections at BIAC-5 3T (MR750) scanner===== 
-=== BIAC5 3T -- Darwin computer===+==== BIAC5 3T --  
 +Darwin computer====
 Darwin is our primary stimulus presentation computer.  It is usually connected to the monitor on the left.\\ Darwin is our primary stimulus presentation computer.  It is usually connected to the monitor on the left.\\
 Darwin has the following peripheral hardware connected: Darwin has the following peripheral hardware connected:
Line 6: Line 7:
   * Second monitor video output connected to KVM switch (CPU 2)   * Second monitor video output connected to KVM switch (CPU 2)
   * Stereo sound output to audio switch boxes (CPU1 - switch 1)   * Stereo sound output to audio switch boxes (CPU1 - switch 1)
-  * NeuroScan 4-button response box via E-Prime SRbox (COM1: 19200 baud, 8 bits, no parity)+  * E-Prime SRbox (COM1: 19200 baud, 8 bits, no parity)
   * GE scanner cardiac/respiratory cable (COM4)   * GE scanner cardiac/respiratory cable (COM4)
   * Serial cable to Kulpe computer (COM3: 56K baud, 8 bits)   * Serial cable to Kulpe computer (COM3: 56K baud, 8 bits)
-  * Serial cable to KVM video switch (COM2) 
   * Current Design 8-button serial response device (USB keyboard device, default mode)   * Current Design 8-button serial response device (USB keyboard device, default mode)
     * button box mode: "HHSC-2x4-C" response box     * button box mode: "HHSC-2x4-C" response box
Line 15: Line 15:
       * must check this mode if power is cycled to the interface       * must check this mode if power is cycled to the interface
  
-  * MagConcepts Joystick (USB Gaming device)+  * Current Design 2 axis, 2 button joystick 
 +    * autoconfigure 
 +    * HID Joystick 
 +    * USB - Tethyx 
 +    * after use switch back to button box with above settings 
   * Measurement Computing Analog/Digital data acquisition device (USB-1208FS, dev=0, 8 a/d chans)   * Measurement Computing Analog/Digital data acquisition device (USB-1208FS, dev=0, 8 a/d chans)
      * to reset AD device disconnect USB cable.      * to reset AD device disconnect USB cable.
Line 21: Line 26:
   * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0)   * Scanner trigger cable connected via SRbox (code=16), and MeasComp analog (ch 5) and digital (B0)
   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse   * Scanner trigger is also connected to the MCC counter pin (CTR), this would show up as a number increase NOT a positive pulse
-  * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor)+  * Biopac belt respiratory signal connected as MeasComp analog input (ch 0, w/ 1Kohm resistor), biopac analog ch4
   * Biopac cardiac signal connected as MeasComp analog input (pulse ch3, OxSat ch4), biopac analog ( o2 ch3, pulse wave ch7, pulse rate ch11)   * Biopac cardiac signal connected as MeasComp analog input (pulse ch3, OxSat ch4), biopac analog ( o2 ch3, pulse wave ch7, pulse rate ch11)
   * BioPac GSR signal connected as MeasComp analog input (ch 1)   * BioPac GSR signal connected as MeasComp analog input (ch 1)
-  * BioPac EGG signal connected as MeasComp analog input (ch 2)+  * <del>BioPac EGG signal connected as MeasComp analog input (ch 2)</del>
   * Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input   * Measurement Computing Box, DigPort-A0 Output to Analog Ch6 In, to BioPac Analog 8 input
   * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In   * Measurement Computing Box, DigPort-A1 Output to Analog Ch7 In
-=== BIAC5 3T -- Kulpe computer=== + 
-Kulpe is our accesory computer. It is usually connected to the monitor on the right.\\+==== BIAC5 3T -- Kulpe computer==== 
 +Kulpe is  
 +our accessory computer. It is usually connected to the monitor on the right.\\
 Kulpe has the following peripheral hardware connected: Kulpe has the following peripheral hardware connected:
   * Keyboard, video, and mouse connected to KVM video switch (CPU 3)   * Keyboard, video, and mouse connected to KVM video switch (CPU 3)
   * BioPac communication (RJ45) cable   * BioPac communication (RJ45) cable
   * Serial cable to Darwin computer (COM1)   * Serial cable to Darwin computer (COM1)
-=== BIAC5 3T -- Other devices=== + 
-  * DVD player, video output connected to KVM switch (CPU 5) +==== BIAC5 3T -- Other devices==== 
-  * DVD player, sound connected to Audio switch (DVD - switch 3) +  * DVD player connected to HDMI switch 
-  * Stereo sound jack for I-pod, MP3, etc connected to Audio switch (Aux - switch 4) + 
-=== Video Switch Connections === + 
-== Source Devices == +==== Video Switch Connections ==== 
-  * CPU1 = Primary Display Computer (Darwin), primary video output +[[biac:experimentalcontrol:hdmi|HDMI Video Switcher Info]] 
-  * CPU2 = Primary Display Computer (Darwin), secondary video output + 
-  * CPU3 = Secondary/Eyetracker Computer (Kulpe) +=== Source Devices === 
-  * CPU4 Not connected +  * IN1 = Primary Display Computer (Darwin), primary video output 
-  * CPU5 DVD player +  * IN2 = Primary Display Computer (Darwin), secondary video output 
-  * CPU6 = Not connected +  * IN3 = Secondary/Eyetracker Computer (Kulpe) 
-  * CPU7 = Not connected +  * IN4 DVD Player 
-  * CPU8 = Not connected +  * IN5 Not connected 
-== Output Devices == +  * IN6 = Not connected 
-  * OUT1 = <del>Left Monitor</del> (faulty port)+  * IN7 = Not connected 
 +  * IN8 = Not connected 
 + 
 +=== Output Devices === 
 +  * OUT1 = Left Monitor
   * OUT2 = Middle Monitor   * OUT2 = Middle Monitor
   * OUT3 = Right Monitor   * OUT3 = Right Monitor
   * OUT4 = Projector   * OUT4 = Projector
-  * OUT5 = Not connected+  * OUT5 = Headphones
   * OUT6 = Not connected   * OUT6 = Not connected
   * OUT7 = Not connected   * OUT7 = Not connected
-  * OUT8 = Left Monitor +  * OUT8 = Not connected 
-== Default Configuration "Stimulus to Subject" == + 
-Note: If you double-click the "Reset Video Switch" icon on the desktop, you will get the following configuration: +==== MCC digital channel to BIOPAC digital channel mapping ==== 
-Source ^Output        ^Labels+^MCC ^BIOPAC
-|Darwin 1|<del>Left Monitor</del>|CPU1 -> OUT1+ DA0 “Trig” 
-|Darwin 2|Middle Monitor|CPU2 -> OUT2+ DA1  D9 
-|Kulpe   |Right Monitor |CPU3 -> OUT3+ DA2  D10
-|Darwin 1|Projector     |CPU1 -> OUT4+ DA3  D11
-|DVD     |No device     |CPU5 -> OUT5+ DA4  D12
-|Darwin 1|No device     |CPU1 -> OUT6+ DA5  D13
-|Darwin 1|No device     |CPU1 -> OUT7+ DA6  D14
-|Darwin 1|Left Monitor  |CPU1 -> OUT8|+ DA7 |  D15| 
  
-[[biac:experimentalcontrol:inventory|Back]]\\ +==== See also ==== 
-[[biac:experimentalcontrol:biac6hardware|BIAC6 Scanner]]+  * [[http://www.mccdaq.com/usb-data-acquisition/USB-1208FS%20.aspx|USB-1208FS]] 
 +  * [[http://www.measurementcomputing.com|Measurement Computing Inc.]] 
 +  [[http://www.measurementcomputing.com/PDFmanuals/sm-ul-user-guide.pdf|Universal Library User Guide]] 
 +  * [[http://www.biopac.com/Manuals/mp_hardware_guide.pdf|biopac manual]]
  
-See also:\\ +[[biac:experimentalcontrol:biac6hardware|BIAC6 Scanner]]\\ 
-[[http://www.mccdaq.com/usb-data-acquisition/USB-1208FS%20.aspx|USB-1208FS]],[[http://www.measurementcomputing.com|Measurement Computing Inc.]],[[http://www.measurementcomputing.com/PDFmanuals/sm-ul-user-guide.pdf|Universal Library User Guide]] +[[biac:experimentalcontrol:inventory|Back]]
-[[http://www.biopac.com/Manuals/mp_hardware_guide.pdf|biopac manual]]+
  
biac/experimentalcontrol/biac5hardware.txt · Last modified: 2023/03/24 18:40 by cmp12