 ===== Recording physiological signals in real-time===== ===== Recording physiological signals in real-time=====
  
-ShowPlay is designed to automatically record a variety of behavioral variables during any real-time paradigm.  Behavioral recording is controlled by a few standard control variables. For recording physiological signals such as heart-beat or repiration you must have appropriate physiological transducer hardware installed and connected to your computer. Once enabled, physiological signals are recorded throughout every ShowPlay paradigm without any modification to the paradigm itself.+ShowPlay is designed to automatically record a variety of behavioral variables during any real-time paradigm.  Behavioral recording is controlled by a few standard control variables. For recording physiological signals such as heart-beat or repiration you must have appropriate physiological transducer hardware installed and connected to your computer. Once enabled, behavioral signals are recorded throughout every ShowPlay paradigm without any modification to the paradigm itself. 
  
 Recording physiological signals involves 3 steps: Recording physiological signals involves 3 steps:
Line 9: Line 9:
   * 3 - connecting the physiological transducers to the subject and verifying their signals   * 3 - connecting the physiological transducers to the subject and verifying their signals
  
-**Step 1 - Configuring the computer hardware**  +**Step 1 - Configuring the computer hardware**\\ 
-Using CIGAL'**Settings** menu, select: **Configuration Settings**+At the BIAC scanners, the default **sysconfig.imp** file automatically initializes: 
 +  graphics - the display screen, keyboard, mouse, and most USB response boxes 
 +  srbox - the EPrime Stimulus/Response box (also used for reading the scanner trigger signal) 
 +  meascomp - the Measurement Computing analog/digital box (used for all Biopac physio i/o) 
 +  eyetracker - connection to 2nd computer to read Viewpoint eyetracking signals\\ 
 +If those are all the devices you need you do not need to change the configuration.
  
-**Step 2 - Setting the software control variables**+If you do want to use different hardware devices, use CIGAL's **Settings** menu to create customized hardware initialization , select: **Configuration Settings** 
 + 
 +I recommend turning on the SRBox (set order=2) to enable the scanner to trigger your tasks. 
 + 
 +Physiological signals (cardiac, respiration, GSR) are analog voltages converted to digital values by the Measurement Computing Analog/Digital converter box.  You must therefore configure CIGAL to initialize the MeasComp box (e.g. set order=3 for meascomp). 
 + 
 +If you want to record eye-position as well you can turn on the eyetracker (order=4). 
 + 
 +   
 +**Step 2 - Setting the software control variables**\\
 Using CIGAL's **Settings** menu, select: **Hardware Settings** Using CIGAL's **Settings** menu, select: **Hardware Settings**
  
-**Step 3 - Verifying physiological transducer signals**+Turn on the data channels you want to record. These are typically **digio**, **keybd/mouse**, **cardiac**, **respiration**, and **eye-position**.  The channel numbers should be correct by default.  
 +For a list of all hardware and channel connections at the BIAC scanners check [[biac:experimentalcontrol:inventory|Device Inventory]]. 
 + 
 +To record efficiently on the MeasComp box, click the **analog scan sampling** box **On**. 
 + 
 +**Step 3 - Verifying physiological transducer signals**\\ 
 Using CIGAL's **Display** menu, select: **Show Behavior** and then choose **Real-time values**. Using CIGAL's **Display** menu, select: **Show Behavior** and then choose **Real-time values**.
  
  
 **See Also:**\\ **See Also:**\\
 +
 +[[biac:experimentalcontrol:inventory|Device connections at BIAC]]
 +
 [[jvs:cigal:showplay:manual:tutorial|ShowPlay Tutorial]],  [[jvs:cigal:showplay:manual:tutorial|ShowPlay Tutorial]], 