jvs:cigal:showplay:manual:chapter1:physio
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
jvs:cigal:showplay:manual:chapter1:physio [2013/08/20 21:17] – voyvodic | jvs:cigal:showplay:manual:chapter1:physio [2015/05/13 16:12] – voyvodic | ||
---|---|---|---|
Line 2: | Line 2: | ||
===== Recording physiological signals in real-time===== | ===== Recording physiological signals in real-time===== | ||
- | ShowPlay is designed to automatically record a variety of behavioral variables during any real-time paradigm. | + | ShowPlay is designed to automatically record a variety of behavioral variables during any real-time paradigm. |
Recording physiological signals involves 3 steps: | Recording physiological signals involves 3 steps: | ||
Line 9: | Line 9: | ||
* 3 - connecting the physiological transducers to the subject and verifying their signals | * 3 - connecting the physiological transducers to the subject and verifying their signals | ||
- | **Step 1 - Configuring the computer hardware** | + | **Step 1 - Configuring the computer hardware**\\ |
- | Using CIGAL' | + | At the BIAC scanners, the default |
+ | | ||
+ | | ||
+ | | ||
+ | | ||
+ | If those are all the devices you need you do not need to change the configuration. | ||
- | **Step 2 - Setting the software control variables** | + | If you do want to use different hardware devices, use CIGAL' |
+ | |||
+ | I recommend turning on the SRBox (set order=2) to enable the scanner to trigger your tasks. | ||
+ | |||
+ | Physiological signals (cardiac, respiration, | ||
+ | |||
+ | If you want to record eye-position as well you can turn on the eyetracker (order=4). | ||
+ | |||
+ | |||
+ | **Step 2 - Setting the software control variables**\\ | ||
Using CIGAL' | Using CIGAL' | ||
- | **Step 3 - Verifying physiological transducer signals** | + | Turn on the data channels you want to record. These are typically **digio**, **keybd/ |
+ | For a list of all hardware and channel connections at the BIAC scanners check [[biac: | ||
+ | |||
+ | To record efficiently on the MeasComp box, click the **analog scan sampling** box **On**. | ||
+ | |||
+ | **Step 3 - Verifying physiological transducer signals**\\ | ||
Using CIGAL' | Using CIGAL' | ||
**See Also:**\\ | **See Also:**\\ | ||
+ | |||
+ | [[biac: | ||
+ | |||
[[jvs: | [[jvs: | ||
[[jvs: | [[jvs: |