fScan Reference Manual, Chapter 2 (CmdLineOptions): stability

Stability -- Calculate displacements of center-of-mass

usage: -stability flag outname refimg slice maxpct

  • FLAG - can take on the following values:
    • 0 - read dx/dy values for registration; OUT is treated as IN file/rec
    • 1 - generate dx/dy/dz plots for each time point
    • 2 - generate dx/dy/di plots for each slice separately
    • 4 - censor images where dx or dy is greater than MAXPCT
    • 8 - use the most frequent position as reference (otherwise use mean value)
    • 3 - generate all plots (default)
  • REFIMG - reference time point for image registration (default=0)
  • SLICE - If specified, only that slice is done, otherwise all.
  • MAXPCT - Used when motion censoring (FLAG & 4). Images with displacement greater than MAXPCT of a voxel will be omitted from further analysis (default MAXPCT = 25%).

See Also:
fScan Home, fScan Manual, CmdLineOptions, Manual Help