biac:analysis:topup_correction
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
biac:analysis:topup_correction [2019/02/21 19:33] – cmp12 | biac:analysis:topup_correction [2019/09/04 17:24] – cmp12 | ||
---|---|---|---|
Line 7: | Line 7: | ||
There will be two series of single timepoint EPI images. | There will be two series of single timepoint EPI images. | ||
- | You need to calculate readout time in seconds ( the physical time it takes to get the acquisition matrix of a single slice ) and get the polarity direction ( phase encode direction ). | + | You need to calculate readout time in seconds |
the readout time in seconds for the parameter file will be: | the readout time in seconds for the parameter file will be: | ||
Line 15: | Line 15: | ||
</ | </ | ||
+ | unfortunately at this point the polarity of the images will have to be determined from visual inspection. we aren't provided enough information in the metadata to give an entry into the BXH file ( yet ). | ||
+ | |||
+ | Here is a rough guide to help with inspection. | ||
+ | {{: | ||
- | the polarity for the entry will have to be determined from the **seriesdescription**, | ||
reverse will be " | reverse will be " | ||
Line 62: | Line 65: | ||
applytopup --imain=../ | applytopup --imain=../ | ||
applytopup --imain=../ | applytopup --imain=../ | ||
+ | </ | ||
+ | |||
+ | If you have the scenario where the functional data was acquired with acceleration, | ||
+ | |||
+ | < | ||
+ | echospacing in the BXH header is in microseconds | ||
</ | </ | ||
Line 192: | Line 201: | ||
there are 2 scenarios that typically apply here | there are 2 scenarios that typically apply here | ||
- | 1) a short acquisition with RPE B0s | + | 1) DWI and a short acquisition with RPE B0s |
- | 2) an entire | + | 2) 2 entire |
In both scenarios it is important to create your data with normal phase encoding direction first, followed by reversed. | In both scenarios it is important to create your data with normal phase encoding direction first, followed by reversed. | ||
Line 200: | Line 209: | ||
==== Prepare your input datasets ==== | ==== Prepare your input datasets ==== | ||
+ | |||
+ | Specify that a set of images (typically b=0 volumes) will be provided for use in inhomogeneity field estimation only | ||
For scenario 1, create your blip up / blip down B0 data the same way as above. | For scenario 1, create your blip up / blip down B0 data the same way as above. | ||
< | < | ||
- | bxhselect --timeselect 0 bia6_00197_012.bxh bu | + | bxhselect --timeselect 0 bi |
+ | a6_00197_012.bxh bu | ||
bxhselect --timeselect 0 bia6_00197_013.bxh bd | bxhselect --timeselect 0 bia6_00197_013.bxh bd | ||
fslmerge -t bud bu.nii.gz bd.nii.gz | fslmerge -t bud bu.nii.gz bd.nii.gz | ||
Line 226: | Line 238: | ||
</ | </ | ||
- | The last step seems redundant, but there is an issue with how mrtrix3 tools are handling the multi-shell GE data produced on our scanners. | + | The last step seems redundant, but there is an issue with how mrtrix3 tools are handling the multi-shell GE data produced on our scanners. |
==== Run dwipreproc -rpe_pair ==== | ==== Run dwipreproc -rpe_pair ==== | ||
Line 233: | Line 245: | ||
< | < | ||
- | dwipreproc | + | dwipre |
+ | proc dwi.mif dwi_corr.mif -rpe_pair -se_epi bud.nii.gz -pe_dir AP -readout_time 0.10656 | ||
-rpe_pair specifies you're providing a pair of B0s ( regular, reversed ) | -rpe_pair specifies you're providing a pair of B0s ( regular, reversed ) | ||
Line 250: | Line 263: | ||
===== Scenario 2 ===== | ===== Scenario 2 ===== | ||
- | You have an entire acquisition with the same gradient table as your DWI sequence, but with reverse phase encoding. | + | You have an entire acquisition with the same gradient table as your DWI sequence, but with reverse phase encoding. This information will be used to perform a recombination of image volumes (each pair of volumes with the same b-vector but different phase encoding directions will be combined together into a single volume). |
Calculate the readout time in the same way as above | Calculate the readout time in the same way as above | ||
Line 260: | Line 273: | ||
< | < | ||
#concat the 2 series ( regular, reversed ) | #concat the 2 series ( regular, reversed ) | ||
- | bxh_concat | + | bxh_concat |
+ | 7_LAS.bxh bia6_00260_008_LAS.bxh both | ||
#extract the gradients | #extract the gradients | ||
- | extractdiffdirs --fsl both bvecs bvals | + | extractdiffdirs --fsl both.bxh bvecs bvals |
#convert to mif | #convert to mif | ||
Line 285: | Line 299: | ||
dwipreproc dwi.mif dwi_corr.mif -rpe_all -pe_dir AP -readout_time 0.10656 -debug | dwipreproc dwi.mif dwi_corr.mif -rpe_all -pe_dir AP -readout_time 0.10656 -debug | ||
- | -rpe_all signals that you've replicated | + | -rpe_all signals that you've replicated |
+ | A | ||
+ | LL the directions with a rpe acquisition | ||
-pe_dir is the phase encode direction of your regular acquisition | -pe_dir is the phase encode direction of your regular acquisition | ||
-readout_time from above | -readout_time from above | ||
</ | </ | ||
+ | |||
+ | {{ : | ||
biac/analysis/topup_correction.txt · Last modified: 2024/06/21 15:44 by 127.0.0.1