biac:analysis:topup_correction
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
biac:analysis:topup_correction [2019/09/04 15:49] – cmp12 | biac:analysis:topup_correction [2021/08/24 16:04] – cmp12 | ||
---|---|---|---|
Line 17: | Line 17: | ||
unfortunately at this point the polarity of the images will have to be determined from visual inspection. we aren't provided enough information in the metadata to give an entry into the BXH file ( yet ). | unfortunately at this point the polarity of the images will have to be determined from visual inspection. we aren't provided enough information in the metadata to give an entry into the BXH file ( yet ). | ||
- | Here is a rough guide to help with inspection: | + | Here is a rough guide to help with inspection. Take note of the eyeballs being crushed in for AP and stretched out for PA. Below shows the PEPOLAR images in red/blue on top of a mean functional. |
- | {{ : | + | {{: |
Line 66: | Line 65: | ||
applytopup --imain=../ | applytopup --imain=../ | ||
applytopup --imain=../ | applytopup --imain=../ | ||
+ | </ | ||
+ | |||
+ | If you have the scenario where the functional data was acquired with acceleration, | ||
+ | |||
+ | < | ||
+ | echospacing in the BXH header is in microseconds | ||
</ | </ | ||
Line 209: | Line 214: | ||
For scenario 1, create your blip up / blip down B0 data the same way as above. | For scenario 1, create your blip up / blip down B0 data the same way as above. | ||
< | < | ||
- | bxhselect --timeselect 0 bi | + | bxhselect --timeselect 0 bia6_00197_012.bxh bu |
- | a6_00197_012.bxh bu | + | |
bxhselect --timeselect 0 bia6_00197_013.bxh bd | bxhselect --timeselect 0 bia6_00197_013.bxh bd | ||
fslmerge -t bud bu.nii.gz bd.nii.gz | fslmerge -t bud bu.nii.gz bd.nii.gz | ||
Line 240: | Line 244: | ||
< | < | ||
- | dwipre | + | dwifslpreproc |
- | proc dwi.mif dwi_corr.mif -rpe_pair -se_epi bud.nii.gz -pe_dir AP -readout_time 0.10656 | + | |
-rpe_pair specifies you're providing a pair of B0s ( regular, reversed ) | -rpe_pair specifies you're providing a pair of B0s ( regular, reversed ) | ||
Line 294: | Line 297: | ||
dwipreproc dwi.mif dwi_corr.mif -rpe_all -pe_dir AP -readout_time 0.10656 -debug | dwipreproc dwi.mif dwi_corr.mif -rpe_all -pe_dir AP -readout_time 0.10656 -debug | ||
- | -rpe_all signals that you've replicated | + | - rpe_all signals that you've replicated |
- | A | + | - pe_dir is the phase encode direction of your regular acquisition |
- | LL the directions with a rpe acquisition | + | - readout_time from above |
- | -pe_dir is the phase encode direction of your regular acquisition | + | |
- | -readout_time from above | + | |
</ | </ | ||