Line 9: Line 9:
   * 3 - connecting the physiological transducers to the subject and verifying their signals   * 3 - connecting the physiological transducers to the subject and verifying their signals
  
-**Step 1 - Configuring the computer hardware** +**Step 1 - Configuring the computer hardware**\\
 Using CIGAL's **Settings** menu, select: **Configuration Settings** Using CIGAL's **Settings** menu, select: **Configuration Settings**
  
-**Step 2 - Setting the software control variables**+I recommend turning on the SRBox as device 2 (set order=2) to enable the scanner to trigger your tasks. 
 + 
 +Physiological signals (cardiac, respiration, GSR) are analog voltages converted to digital values by the Measurement Computing Analog/Digital converter box.  You must therefore configure CIGAL to initialize the MeasComp box (e.g. set order=3 for meascomp). 
 + 
 +If you want to record eye-position as well you can turn on the eyetracker (order=4). 
 + 
 +On BIAC6, the **userconfig.imp** file I typically use has these lines: 
 +  srbox 1 - 5 
 +  meascomp 0 8 - - - - - - 2 
 +  eyetracker 3 
 +   
 +**Step 2 - Setting the software control variables**\\
 Using CIGAL's **Settings** menu, select: **Hardware Settings** Using CIGAL's **Settings** menu, select: **Hardware Settings**
  
-**Step 3 - Verifying physiological transducer signals**+Turn on the data channels you want to record. These are typically **digio**, **keybd/mouse**, **cardiac**, **respiration**, and **eye-position**.  The channel numbers should be correct by default.  
 +For a list of all hardware and channel connections at the BIAC scanners check [[biac:experimentalcontrol:inventory|Device Inventory]]. 
 + 
 +To record efficiently on the MeasComp box, click the **analog scan sampling** box **On**. 
 + 
 +**Step 3 - Verifying physiological transducer signals**\\ 
 Using CIGAL's **Display** menu, select: **Show Behavior** and then choose **Real-time values**. Using CIGAL's **Display** menu, select: **Show Behavior** and then choose **Real-time values**.
  
  
 **See Also:**\\ **See Also:**\\
 +
 +[[biac:experimentalcontrol:inventory|Device connections at BIAC]]
 +
 [[jvs:cigal:showplay:manual:tutorial|ShowPlay Tutorial]],  [[jvs:cigal:showplay:manual:tutorial|ShowPlay Tutorial]], 
 [[jvs:cigal:showplay|ShowPlay Home]],  [[jvs:cigal:showplay|ShowPlay Home]], 
jvs/cigal/showplay/manual/chapter1/physio.txt · Last modified: 2024/06/21 15:44 by 127.0.0.1