CIGAL Reference Manual, Chapter 6 (RealTime): r_logval

r_logval -- Enter a short integer value in the runlog

usage: r_logval opflg eflag ltime Databuf

R_LOGVAL is a REALTIME operator. It makes an entry in the program's RUNLOG, which is a data matrix specified when the REALTIME processor was started (see REALTIME(2)). This operation records the current time and EFLAG value as well as the value in DATABUF in the log. The DATABUF value is stored as a short integer (16 bits). The R_LOGVAL entry is identified in the log by the opcode value 58, to indicate that this was a R_LOGVAL operation. For a complete list of the opcode values for all REALTIME operators see RT_OPCODES(6).

See Also:
REALTIME(2), RT_OPCODES(6)

CIGAL Home, CIGAL Manual, RealTime List, Manual Help